Site Map
FAST Quant® Frequently Asked Questions

 

FAST Quant is for research only, not for diagnostic use.

Questions

1.

What's the content of each of the human and mouse arrays?

2. I need to quantify other elements than those provided in the FAST Quant kit. What does S&S Bioscience recommend?
3. What is the surface used on the FAST® Slides?
4. What is the format of the FAST Slides provided in the kit?
5. What's the size of the FAST Slides?
6. Where should I set my standard curve on the FAST Slides?
7. What does S&S recommend as the starting standard curve dilution for each cytokine?
8. What's the spot density?
9. What's the distance between spots?
10. How do I ensure the incubation chambers are well-applied onto the FAST Slides so no liquid leaks from one pad to the next?
11. How should I store the antigens and antibodies?
12. What is the detection method to be used with FAST Quant?
13. How do I order FAST Quant?
14. I would like to try protein array technology but don't have access to a fluorscent scanner and personnel. How can I proceed?


Answers

1. Click here for the content of each of the human and mouse arrays?
2. Schleicher & Schuell BioScience has a library of 60 human and mouse antibody pairs. Our custom array facility will be able to design and build an array for you to meet your needs. Call within North and South America: (800) 245-4024, option 3 to obtain information on our custom service. Within Europe, CIS, Africa, Asia/Pacific and the Middle East please call: +49 (0)5561-791-673.
3. Schleicher & Schuell Bioscience's FAST Slides are coated with a 3-D nitrocellulose surface. Nitrocellulose has become the industry standard for protein arraying due to its high capacity and positive influence on protein binding and stability. These surface characteristics provide the foundation for FAST Quant performance as a powerful tool to provide multiplexed data acquisition in a microarray format.
4. The kit contains 4 FAST Slides with 16 pre-arrayed pads on each.
5. FAST Quant is built on standard S&S 16 pad FAST Slides. The slides are standard 25 mm x 76 mm microscope slides so they are compatible with standard microarray scanners. The arrays are 6 mm x 6 mm on 9 mm spacing. Once inserted into the FAST Frame, (offered by Schleicher & Schuell Bioscience and recommended for the use of FAST Quant) the FAST Slides are compatible with the commonly used liquid handling instrumentation as well as with multi-channel pipettors.

S&S highly recommends setting up the dilutions for the standard curve on the first left column of pads in the FAST Frame so as to make it easier to process the slides with ArrayVision FAST. For ease of analysis, incubate the starting concentration of antigens in the uppermost well.
6. S&S highly recommends setting up the dilutions for the standard curve on the first left column of pads in the FAST Frame so as to make it easier to process the slides with ArrayVision FAST. For ease of analysis, incubate the starting concentration of antigens in the uppermost well.
7.
FAST Quant Human TH1/TH2
 
FAST Quant Mouse TH1/TH2
 
FAST Quant Human II
Antigen
10X Ag
Cocktail Stock Concentration
 
Antigen
10X Ag
Cocktail Stock Concentration
 
Antigen
10X Ag
Cocktail Stock Concentration
IL-1b
100 ng/ml
 
IL-1b
120 ng/ml
 
IL-1b
100 ng/ml
IL-2
100 ng/ml
 
IL-2
120 ng/ml
 
IL-2
100 ng/ml
IL-4
100 ng/ml
 
IL-4
120 ng/ml
 
IL-4
100 ng/ml
IL-5
100 ng/ml
 
IL-5
120 ng/ml
 
IL-6
100 ng/ml
IL-6
100 ng/ml
 
IL-6
120 ng/ml
 
IL-8
100 ng/ml
IL-10
500 ng/ml
 
IL-10
200 ng/ml
 
GM-CSF
100 ng/ml
IL-13
500 ng/ml
 
IL-13
200 ng/ml
 
IL-10
500 ng/ml
IFNg
500 ng/ml
 
IFNg
120 ng/ml
 
IL-12p70
500 ng/ml
TNFa
100 ng/ml
 
TNFa
120 ng/ml
 
MCP-1
100 ng/ml
           
RANTES
100 ng/ml

FAST Quant Mouse II
 
FAST Quant Human Angiogenesis
 
FAST Quant Human Chemokine
Antigen
10X Ag
Cocktail Stock Concentration
 
Antigen
10X Ag
Cocktail Stock Concentration
 
Antigen
10X Ag
Cocktail Stock Concentration
IL-1b
120 ng/ml
 
Angiogenin
100 ng/ml
 
IP-10
500 ng/ml
IL-2
120 ng/ml
 
Angiopoietin-2
500 ng/ml
 
Eotaxin
100 ng/ml
IL-4
120 ng/ml
 
KGF
500 ng/ml
 
RANTES
100 ng/ml
IL-6
120 ng/ml
 
PDGF-BB
500 ng/ml
 
MCP-1
100 ng/ml
IL-10
200 ng/ml
 
FGF-basic
500 ng/ml
 
MCP-2
100 ng/ml
IL-12p70
200 ng/ml
 
TIMP-1
500 ng/ml
 
MCP-3
100 ng/ml
GM-CSF
120 ng/ml
 
ICAM-1
500 ng/ml
 
MCP-4
100 ng/ml
IFNg
120 ng/ml
 
VEGF
100 ng/ml
 
IL-8
100 ng/ml
RANTES
120 ng/ml
       
MIP-1a
100 ng/ml
8. The spot density is 36 spots/36 mm2
9. The pitch (center-to-center distance) between two spots is 500 µm.
10.

NOTE: Do not overlap any portion of a pad with the chamber. Do not touch the surface of the pads with anything other than the substances mentioned in this protocol at anytime during the experiment. Take care that pipette tips do not contact the pads and damage them.

  1. The incubation chambers are marked for easy orientation with an indented circle on the upper right corner. The FAST Slides are marked with a laser-etched circle on their upper right corner.

  2. Apply the incubation chamber to the FAST Slide by matching the circle on the FAST Slide with the circle on the chamber. The chamber/slide assembly can then be inserted into the FAST Frame, the end opposite the circle first. Align the assembly with 1 of the 4 positions of the FAST Frame and push it completely into the frame beneath the plastic side rails. Repeat for all chamber/slide assemblies used.
11. As soon as you receive the box containing the antigens and antibodies, open it, retrieve the four vials and place them in a freezer to store at -20C.
12. The detection method used is fluorescence. We recommend the sue of streptavidin-Cy™5 (Amersham Biosciences cat# PA 450001,1 mg/bottle) or an equivalent to Cy5.
13.

Ordering information: FAST Quant product number is 10486031.

Within North & South America
Schleicher & Schuell BioScience, Inc.
63 Community Drive
Sanford, ME 04073
Phone: 800-245-4024
Fax: (207) 459-3099
techserv@schleicher-schuell.com
Within Europe, CIS, Asia/Pacific, Africa
and the Middle East

Schleicher & Schuell BioScience, GmbH.
Hahnestrasse 3
37586 Dassel
Germany
Phone: (+49) 5561-791-463
Fax: (+49) 5561-791-583
salesbio@schleicher-schuell.com
14. S&S recognizes that many of our customers are new to protein microarray technology. That is why we offer a custom processing service. You can send us your samples and we will process and scan the arrays, and send you back tabulated data. Call within North and South America: (800) 245-4024, option 3 to obtain information on our custom service. Within Europe, CIS, Africa, Asia/Pacific and the Middle East please call: +49 (0)5561-791-673.


FAST Quant is for research only, not for diagnostic use.

 

 

 

© 2005 Whatman Schleicher & Schuell